| Maximum Steam Output |
300 - 900 kg/hr |
| Maximum Heat Output |
0.7 - 2 MBTU/Hr
187000 - 550000 Kcal/Hr
|
| |
|
| Fuel Consumption |
25 - 75Ltr/Hr |
| |
|
| Standard Working Pressure |
4 - 6 Barg. |
| Maximum Working Pressure |
7 Barg. |
| Electrical Requirements - Generator |
380 - 480V, 3 phase, 50/60Hz |
| Multiple Input Transformer |
Input 380-415-440-460-480V, 3 phase, 60Hz
Output 230V
|
| Power Requirements - Generator |
2.75KW |
| Electrical Requirements - Cabin Lighting |
240 Volt, single phase |
| Power Requirements - Lighting |
300 Watt |
| Cabling |
BS6883, Braided Shipscable |
| |
|
| Container Type |
10 foot container to EN 12079 |
| Size |
10' x 8' x 8' |
| Weight |
4000kg |
| SWL |
7000kg |
| Outlet Connection |
1” Weco Fig 200 Male |
| Standard Safety Devices |
Flame Failure by Flame Sensor
Maximum Pressure Pressostat set at 7 Barg
Safety Valve set at 9 Barg. |
| |
|
| Certification Steam Generator |
DNV Safe Area Open Deck |
| The unit contains a water tank, diesel tank, chemical
dosing unit and water softener inside the container. |
| |
|
| Steam Hoses |
|
| Size, Number and Length |
1” in 10 and 20 metre lengths |
| Maximum Working Pressure |
10 Barg. |
| Coupling |
1” Weco fig.200 |
| Coding |
BS5342 Type 2A |
| Steam Hoses are individually labelled. |